630A LT Distribution Panel (8-Way)
Heavy-duty 630A LT distribution panel for large industrial complexes and power distribution centers. Includes advanced protection relays and remote monitoring capability.
Ref. LTP-630-8W · Lead time 5–7 weeks · Made to order from Hapur
See full engineering specification & variants
Key Features
Recommended For
Specifications
| Specification | Value |
|---|---|
| Main Rating | 630A |
| Branch Ways | 8 ways |
| Input Voltage | 415V, 3-Phase, 4-Wire |
| Frequency | 50/60 Hz |
| Enclosure Type | IP54, Stainless Steel |
| Bus Bar Rating | Copper, 1000A capable |
| Weight | 750 kg |
| Warranty | 2 years |
Reading the specification
What these numbers mean for your installation
A datasheet tells you what the unit does. This is what each figure changes about how you specify, feed and site it — worked out for the ~300 kVA specifically, not the range in general.
453 kVA
A 630 A incomer on a 415 V three-phase supply carries about 453 kVA at full rating. We list this panel at ~300 kVA because continuous loading is normally held well below the breaker rating — the difference is your diversity and future-expansion margin.
8 ways
8 ways of protected outgoing feeders. Allow one spare way at commissioning: adding a feeder later means de-energising the whole board, and on a working shop floor that shutdown usually costs more than the extra way did.
IP54, Stainless Steel
IP54 is dust-protected and rated against splashing water from any direction — an indoor plant room or a sheltered outdoor position. A fully exposed outdoor location, or a washdown area in food or pharma, needs a higher rating and a canopy; tell us the mounting position and we will build to suit.
Sizing Guide
When is a 630A board the right size?
630 A is a main-incomer board, not a sub-distribution board. It suits a sanctioned load approaching 300–350 kVA: a full production block, a hospital's essential-services supply, or a data centre's mechanical plant. The stainless steel enclosure and Modbus interface earn their place at this rating — a facility this size normally has a BMS, and per-feeder metering over Modbus is what makes energy accounting by line possible without retrofitting meters into a live board later. Eight ways covers a typical split of four production feeders plus HVAC, lighting, UPS and one spare. At 750 kg it needs a load-bearing plinth and mechanical handling for final placement.
Before you order
Where a 630A board goes in, and what the site needs
Typical installations
We supply ~300 kVA most often into large industrial complexes, power distribution substations, data centers and hospital power management, alongside shopping malls and high-rise buildings. What separates those sites is how the outgoing ways get allocated. Two boards of this rating can look identical on the schedule and behave completely differently depending on whether one feeder carries most of the load or the demand is spread evenly across them.
Site preparation
At 750 kg you need a pallet truck at minimum and a level, load-spreading base. Check the route for ramp gradients — a hydraulic truck carrying 750 kg will not climb much of one. Leave working clearance on the terminal side for cable entry and inspection. Sustained ambient above 45 °C, or an enclosed room without cross-ventilation, requires derating — send us the room conditions and we will confirm the rating still holds where you intend to put it.
Adjacent ratings
If a 630A board is not the right size
Sizing rarely lands exactly on a catalogue rating first time. These are the ratings either side of it in the same range — compare the specification before you commit.
400A LT Distribution Panel (6-Way)
Low-tension distribution panel with 400A main capacity and 6-way branch circuits.
View specificationLT Panel160A LT Distribution Panel (4-Way)
Compact low-tension distribution panel with 160A main capacity.
View specificationAlso in the panel range
Different equipment rather than a different size — often specified alongside this on the same project.
200 kVAr APFC Panel
Industrial-grade APFC panel for large power factor correction (200 kVAr).
View specificationAPFC Panel100 kVAr APFC Panel
Mid-range APFC panel for 100 kVAr reactive power compensation.
View specificationAPFC Panel50 kVAr APFC Panel
Automatic power factor correction panel for 50 kVAr reactive power compensation.
View specificationEngineering detail on this configuration
The lt panel pages carry the full design rationale, comparison tables and application notes behind this SKU.
Ready to specify?
Share your load profile. Get a firm proposal in 24 hours.
Send us your kVA requirement, supply voltage range, and site conditions. Our engineer will confirm whether this configuration is correct for your installation, or specify an alternative if needed. No distributors — direct from our factory in Hapur.
Submit load requirements