LT Panel

400A LT Distribution Panel (6-Way)

Robust 400A LT distribution panel designed for reliable power distribution in industrial facilities. Features integrated metering, earth leakage detection, and robust overload protection on all branches.

Rating~200 kVA
Voltage415V AC, 3-Phase
Coolingboth air and oil cooled
Lead Time3–4 weeks

Ref. LTP-400-6W · Lead time 3–4 weeks · Made to order from Hapur

See full engineering specification & variants
400A LT Distribution Panel (6-Way)

Key Features

Main capacity: 400A
6-way branch circuits
IP54 rated enclosure
Integrated ammeter & voltmeter
Earth leakage circuit breaker (ELCB)
Phase failure & phase reversal protection
Thermal & magnetic overload on each branch
Heavy-duty bus bars with tin plating

Recommended For

Manufacturing Facilities
Industrial Buildings
Hospitals
Schools & Colleges
Shopping Complexes
Residential Complexes

Specifications

SpecificationValue
Main Rating400A
Branch Ways6 ways
Input Voltage415V, 3-Phase, 4-Wire
Frequency50/60 Hz
Enclosure TypeIP54
MaterialMild Steel (powder coated)
Weight450 kg
Warranty2 years

Reading the specification

What these numbers mean for your installation

A datasheet tells you what the unit does. This is what each figure changes about how you specify, feed and site it — worked out for the ~200 kVA specifically, not the range in general.

Connected capacity

288 kVA

A 400 A incomer on a 415 V three-phase supply carries about 288 kVA at full rating. We list this panel at ~200 kVA because continuous loading is normally held well below the breaker rating — the difference is your diversity and future-expansion margin.

Outgoing ways

6 ways

6 ways of protected outgoing feeders. Allow one spare way at commissioning: adding a feeder later means de-energising the whole board, and on a working shop floor that shutdown usually costs more than the extra way did.

Enclosure rating

IP54

IP54 is dust-protected and rated against splashing water from any direction — an indoor plant room or a sheltered outdoor position. A fully exposed outdoor location, or a washdown area in food or pharma, needs a higher rating and a canopy; tell us the mounting position and we will build to suit.

Sizing Guide

When is a 400A board the right size?

400 A is the workhorse rating for a mid-sized factory — a sanctioned load around 200 kVA, which in practice covers 15 to 25 machines plus compressors, lighting and office supply. Six ways lets you separate production lines from services, so an earth fault on one line does not drop the whole floor. This is also the board most often paired with a 200–250 kVA servo stabilizer sitting immediately upstream of it. Step up to the 630 A eight-way board if you have a second shift's expansion already sanctioned, or if any single outgoing feeder will exceed 200 A — a heavily loaded way on a six-way board is the configuration we are most often called back to rebuild.

Before you order

Where a 400A board goes in, and what the site needs

Typical installations

We supply ~200 kVA most often into manufacturing facilities, industrial buildings, hospitals and schools & colleges, alongside shopping complexes and residential complexes. What separates those sites is how the outgoing ways get allocated. Two boards of this rating can look identical on the schedule and behave completely differently depending on whether one feeder carries most of the load or the demand is spread evenly across them.

Site preparation

At 450 kg you need a pallet truck at minimum and a level, load-spreading base. Check the route for ramp gradients — a hydraulic truck carrying 450 kg will not climb much of one. Leave working clearance on the terminal side for cable entry and inspection. Sustained ambient above 45 °C, or an enclosed room without cross-ventilation, requires derating — send us the room conditions and we will confirm the rating still holds where you intend to put it.

Adjacent ratings

If a 400A board is not the right size

Sizing rarely lands exactly on a catalogue rating first time. These are the ratings either side of it in the same range — compare the specification before you commit.

Engineering detail on this configuration

The lt panel pages carry the full design rationale, comparison tables and application notes behind this SKU.

Ready to specify?

Share your load profile. Get a firm proposal in 24 hours.

Send us your kVA requirement, supply voltage range, and site conditions. Our engineer will confirm whether this configuration is correct for your installation, or specify an alternative if needed. No distributors — direct from our factory in Hapur.

Submit load requirements