Servo Voltage Stabilizer

325 kVA Servo Voltage Stabilizer

Our 325 kVA Servo Voltage Stabilizer delivers premium performance for large-scale industrial complexes. Features advanced servo technology with superior voltage stability.

Rating325 kVA
Voltage415V AC, 3-Phase
Coolingboth air and oil cooled
Lead Time3–4 weeks

Ref. SVS-325-3PH · Lead time 3–4 weeks · Made to order from Hapur

See full engineering specification & variants
325 kVA Servo Voltage Stabilizer

Key Features

±1% voltage regulation
Servo motor precision control
Response time < 20 ms
Capacity: up to 150% for 30 minutes
Oil-cooled with forced air circulation
IP54 enclosure rating
Advanced multi-phase protection
Remote monitoring capability

Recommended For

Large Manufacturing Plants
Steel Mills
Automotive Facilities
Chemical Plants
Industrial Complexes
Metal Fabrication

Specifications

SpecificationValue
Capacity325 kVA
Input Voltage300V–470V, 3-Phase
Output Voltage415V ±1%
Frequency50/60 Hz
Response Time< 20 ms
Cooling Methodboth air and oil cooled
Weight1300 kg
Warranty3 years

Reading the specification

What these numbers mean for your installation

A datasheet tells you what the unit does. This is what each figure changes about how you specify, feed and site it — worked out for the 325 kVA specifically, not the range in general.

Rated current

452 A per phase

At 415 V three-phase, 325 kVA works out at roughly 452 A per phase. At 452 A you are normally into parallel cable runs per phase rather than a single conductor. Confirm the terminal chamber accepts the number of runs your cable schedule calls for — discovering it does not, on the day of commissioning, is the most common reason installations at this rating slip.

Correction window

300V–470V

The unit holds output at 415V ±1% anywhere between 300 V and 470 V in. Pulling a 300 V supply back up to 415 V means adding 115 V — a 38% lift on the incoming supply, with the series winding carrying roughly 90 kVA of the 325 kVA throughput. Below 300 V it runs out of range, and the answer is a wider-window build, not more kVA.

Response time

< 20 ms

At this rating the stabilizer is feeding a whole section of the floor, so < 20 ms determines whether one machine's inrush propagates into every other machine on the same board. That is the mechanism behind most "random" tripping complaints we are called out to.

Overload headroom

150% for 30 minutes

Direct-on-line starting draws six to eight times full-load current for a few seconds, and 150% for 30 minutes is the margin that absorbs it. At 325 kVA the practical constraint is usually the largest single motor rather than the total: size against that starting current, not against the sum of the nameplates.

Sizing Guide

When is 325 kVA the right choice?

325 kVA is the correct size when a 300 kVA unit would sustain load above 90% during peak production periods. Paper mills with coating lines, large cold-storage warehouses with 8–12 refrigeration compressors, and integrated garment factories where embroidery machines, cutting plotters, and steam presses share a single incomer are typical applications. This is also the size most often chosen for EPC contractors installing at SEZ units where the client specifies 20% spare capacity above connected load as a contractual requirement — the 325 kVA unit gives that margin over a 260–270 kVA calculated load.

Before you order

Where 325 kVA goes in, and what the site needs

Typical installations

We supply 325 kVA most often into large manufacturing plants, steel mills, automotive facilities and chemical plants, alongside industrial complexes and metal fabrication. What separates those sites is duty cycle rather than load. A rating that runs cool on single-shift work sits near the top of its thermal range on a continuous three-shift line, and that is the point at which oil cooling stops being optional.

Site preparation

At 1,300 kg this is forklift work, and the forklift has to be rated for 1,300 kg at the extended reach that placement requires. Confirm floor loading before it arrives — a ground-floor workshop slab is normally adequate, a mezzanine generally is not. Leave working clearance on the terminal side for cable entry and inspection. Sustained ambient above 45 °C, or an enclosed room without cross-ventilation, requires derating — send us the room conditions and we will confirm the rating still holds where you intend to put it.

Ready to specify?

Share your load profile. Get a firm proposal in 24 hours.

Send us your kVA requirement, supply voltage range, and site conditions. Our engineer will confirm whether this configuration is correct for your installation, or specify an alternative if needed. No distributors — direct from our factory in Hapur.

Submit load requirements